travelodge

Facts and Figures

Client – Travelodge

Full Energy Design & Audit

Completion Date 2018

Detail Full energy design for the building including@ primary heating, secondary heating, renewables, fabric, solar gains, lighting, heating and power

When Travelodge embarked on the development of a new hotel in Darlington Energy Gain UK undertook the analysis of the energy losses for the proposed building and presentation of findings on building compliance and renewable energy options to meet a 10% contribution.

Scope Analysis of the energy losses for the proposed building and presentation of findings on building compliance and renewable energy options to meet a 10% contribution.

The dynamic model was built to evaluate building performance. As a complete analysis tool it allows packages in thermal, energy and carbon performance including Part L compliance, solar and mechanical and electrical design.

Numerous cases were modelled, and a number of technologies analysed including: gas boilers, electric space heating, solar PV, solar thermal, CHP, biomass, lighting controls, MVHR and Optimisation.  The results were analysed and the optimum solution offered to the client considering: end user requirements, financial returns, capital expenditure, whole life management, space and planning requirements.

solar (4)

vygon UK

503kWp Solar Photovoltaics
mi vehicle integration case study

Mi Vehicle Integration

Leyland

solar (8)

Camster Herbs

260 KWp Solar Photovoltaics

When Travelodge were planning the development of a new venue in Cheshire Energy Gain UK were commissioned to provide a full energy compliance report, design, supply, install & commission a Solar Photovoltaic System. Travelodge needed to ensure that they met Sbem renewable calculations, as well as ensure that running costs were kept to a minimum by implementing the latest energy reduction technologies.

white-space-18

Project Detail

Client Travelodge

Sector Hospitality

Scope Provide Full Energy Compliance Report, Design, Supply, Install & Commission Solar Photovoltaic System

Technology Solar Photovoltaics

Location Chester

Site Details

Capacity 17.60KWp Feed Three Phase

Azimuth 30 Degrees Pitch 35 Degrees

Shading None Access Scaffold

Components

Mounting On-Roof Mounting System Hilti

Solar Modules Sharp ND 220  Qty of Solar Modules 80

Inverter SMA 17000TL  Qty of Inverters 1

Generation Data

Estimated Annual Output    855 KWP/KWh p/a Carbon Saving 7,894 KgCo2e p/a

*Figures based on PVGIS Data *Figures based on 0.5246 KG CO2 per

white-space-18Travelodge Commission Solar Photovoltaic System

partner logos Solar Photovoltaic System

Travelodge-495xsize-6

Leave a Reply